dilo vacuum sf 6 separating unit

dilo vacuum sf 6 separating unit

Dilo B0464R13 Mobile Vacuum Pump Unit with Solenoid Valves. The mobile vacuum pump unit is convincing by its easy handling. The unit serves for evacuation of air or nitrogen from switchgear. The 40 m³/h vacuum pump enables a final vacuum of < 1 mbar. Thus it is guaranteed that no air / gas mixture is generated and the good. Get Price

[email protected]

News Detail

  • Oil Free Vacuum Pump for Recovery SF6 Gas <1 mbar - DILO

    Oil free vacuum pump units Upgrading SF 6 service carts. The oil free vacuum pump allows for upgrading old SF 6 maintenance devices. Therefore, it is possible to recover the SF 6 gas from the gas compartment to a final vacuum of <1 mbar by using the mobile suction pump. Other features: Separate electric control

    Get Price
  • PDF Mobile Vacuum Pump Unit - Dilo

    MOBILE VACUUM PUMP UNIT SF 6 GAS REFILLING AND EVACUATING DEVICES B046R03 / R13 Mobile vacuum pump unit Technical data for 40 m³/h vacuum pump, fi nal vacuum < 1 mbar: Dimensions: Length 890 mm, Width 610 mm, Height 1,050 mm Weight: 115 kg Operating voltage: 208 - 240 V / 380 - 460 V / 50 - 60 Hz 3-phase current Standard equipment:

    Get Price
  • SF6 gas handling - DILO

    However, DILO separating units allow the SF 6 gas mixture to be purified to the extent that it even meets the standards of IEC 60376 (directive for new SF 6 gas technical quality) with regard to moisture, SF 6 percentage and decomposition products (SO 2).

    Get Price
  • Vacuum test chambers | DILO GmbH

    SF6 leak testing units - from small to extra large Model range LeakScanner SV Vacuum testing of smaller components (without gas handling) This model range with a chamber volume of approx. 50 - 500 l is the ideal solution for testing smaller components where gas handling can take place outside the test chamber.

    Get Price
  • DILO Company, Inc. | World Leader in SF6 Maintenance Equipment

    If you're looking for a SF 6 gas handling specialist that combines quality, innovation, and sustainability with excellent customer service, then DILO is for you. For over 50 years, customers around the world have valued DILO as an important partner for professional and emission-free gas handling.

    Get Price
  • PDF SF Units for GIS Production 6 - DILO

    the SF 6 can be reused in gas compartments. Consequently, costs for storage, disposal, transportation and the expense for new gas can be minimised. The purity degree of the prepared SF 6 gas corresponds to the following standards: IEC 60480 - guideline for used SF 6 gas IEC 60376 - guideline for new SF 6 gas GB/T 12022/2006 - Chinese

    Get Price
  • Oil-free SF6 suction pumps - DILO

    Oil-free suction pump units Upgrading SF 6 service carts. The mobile suction pump allows upgrading old SF 6 maintenance devices. Thus it is possible to recover the SF 6 gas from the gas compartment to a final vacuum of 1 mbar by connecting in series the mobile suction pump.. Other features:. Separate electric control

    Get Price
  • PDF B131R41 Mobile oilfree suction pump unit - DILO

    Mobile oilfree suction pump unit C 3387-04 The mobile suction pump allows upgrading old SF 6 maintenance devices. Thus it is possible to recover the SF 6 gas from the gas compartment to a final vacuum of 1 mbar by connecting in series the mobile suction pump. Mobile oilfree suction pump unit 15 m3/h Final vacuum < 1 mbar

    Get Price
  • PDF SF Gas Handling 6 - eknis.net

    DILO SF 6 gas service cart DILO SF 6 gas storage tank SF 6 circuit breaker the air recovered exhausts into the atmosphere Gas cylinder 1. SF 6 gas recovery 2. Evacuation of air or nitrogen 3. Filling with SF 6 (to operating pressure) Functional diagram for service carts Suction pump Compressor Dry Particle fi lter fi lter Vacuum pump

    Get Price
  • Cheapest sf 6 vacuum separating unit

    Sf6 Gas Refining Machine with Vacuum Pump for Sf6 - SF6 Expert gas valves separating unit manufacturersGet Price! Find Product in Xin Yuan Instrument Factory for SF6 Gas Valves X-VK/F-02/8,Ball Valves X-365-R001 SF6 Gas Valves X-VK/F-02/8 SF6 Gas Ball characteristics of valves during b- A valve for use in a pressurised fluid container comprises a chamber 5 within a hollow body 1 .

    Get Price
  • PDF Mobile Vacuum Pump Unit - Dilo

    MOBILE VACUUM PUMP UNIT SF 6 GAS REFILLING AND EVACUATING DEVICES. C 3382-05 Technical data: Dimensions: L 1,250 mm, W 800 mm, H 1,500 mm 3-phase current Standard equipment: Roots pump, mounted on a vacuum pump, fi nal vacuum 2 x 10-2 mbar Solenoid valve DN50 DILO couplings DN20 and 2 x DN40 Digital vacuum indication in mbar Electric

    Get Price
  • SF6 Gas Room Monitor | DILO

    The SF 6 Gas Room Monitor is new to our outstanding line of emission detection units. This multi-zone device provides continuous detection of SF 6 gas levels in up to 16 separate test zones and can be fitted with an optional two channel 4-20 mA current loop board for connection to remote monitoring equipment.

    Get Price
  • DILO Products - Aspectus Engineering Services Pte Ltd

    SF 6-gas recovery down to < 1 mbar; TM 5.0 B Oil-free Compressor; delivery rate: 6.5 m³/h at medium suction pressure with SF 6; Oil-free suction pump for recovery of SF 6 (15 m³/h, final vacuum < 1 mbar); Vacuum pump for evacuation of air (40 m 3 /h, final vacuum < 1 mbar); Operating and indication of the most important process parameters via 10 multi-touch panel with protective cover

    Get Price
  • Digital Vacuum Gauge | Dilo Company, Inc

    Indication range: 0 - 400 mbar / class 0.1 After having evacuated the air or after the recovery of SF 6 gas the device allows precise determination of the vacuum in gas compartments. The device is protected against overpressure up to p e 9 bar.

    Get Price
  • PDF B078R09 Mini Series - Technical data see page 40 - DILO

    The mobile vacuum pump unit is convincing by its easy handling. The unit serves for evacuation of air or nitrogen from switchgear. The 40 m³/h vacuum pump enables a final vacuum of < 1 mbar. Thus it is guaranteed that no air / gas mixture is generated and the good insulation properties of SF 6 are retained. B078R09 Mini Series - Technical data

    Get Price
  • New SF6 Leakage Test Unit for GIS Components | TD World

    The SF 6 leakage test system developed by DILO allows an integral and fully automatic leak measurement on gas-insulated medium or high voltage components and assemblies. The system's core components are: a vacuum test chamber with diffusion accelerator, a highly sensitive leak measuring system as well as a vacuum pump for evacuation of the

    Get Price
  • Lock Valve 3-1150-R... | Securely separate DILO

    SF 6 gas handling can also be carried out via this integrated DN20 coupling - a useful Two-in-one solution which is perfectly suited for retrofitting as well. The 3-1150-R... lock valve is the perfect match for tight installation conditions.

    Get Price
  • PDF SF GAS DRYING UNIT - de.dilo.com

    Measuring range of SF 6 gas humidity: -55 to +30 °C atmospheric dew point Ambient temperature: 0 to 40 °C Standard equipment: Oilfree DILO compressor (1.6 m³/h [at 50 Hz], 50 bar; 1.9 m³/h [at 60 Hz], 50 bar) Vacuum compressor (3.3 m³/h; fi nal vacuum < 2.0 mbar) 3 dry fi lters (water absorption capacity: 3x 175 g at a dew point of -36

    Get Price
  • DILO - B057R.. - Compact Series - DILO - SF6 Service Carts

    DILO - B057R.. - Compact Series - SF6 Gas Recovery Unit by DILO Armaturen und Anlagen GmbH. This robust series comprises several versions allowing gaseous and liquid SF6 storage. SF6 gas can be recovered to a final vacuum of lt; 5 mbar or 1 mbar and...

    Get Price
  • PDF B046R20 Mobile vacuum pump unit - DILO

    Mobile vacuum pump unit C 3111-05 For evacuation of air or nitrogen This vacuum pump unit is powerful - its nominal suction capacity is 200 m³/h at 50 Hz for quick and reliable evacuation of air to a final vacuum of 1 mbar. This unit is particularly suitable for the evacuation of large gas compartments.

    Get Price
  • DILO Industrial Gas Plant Construction

    DILO Company, Inc. 11642 Pyramid Drive Odessa, FL 33556 Phone: 727-376-5593 E-Mail: [email protected]

    Get Price
  • Glossary - us.dilo.com

    This further helps the liquification of SF 6 gas, thus separating other vapors such as N2, O2 and CF4. In addition, upon the start of the reconditioning process, the contaminated SF 6 gas must be processed through a pre-filter system ensuring oil, moisture and SF 6 gas by-products are captured and scrubbed from the gas.

    Get Price
  • SF6 worker protection | DILO GmbH

    Working protection kit For decomposed SF 6 gas (with neutralization). 3-442-R001. After arc quenching in the circuit breaker solid or gaseous decomposition products are generated the operators have to be protected from effectively.

    Get Price
  • INDUSTRIAL GAS EQUIPMENT | DILO GmbH

    DILO Armaturen und Anlagen GmbH Frundsbergstrasse 36 D-87727 Babenhausen/Schwaben Tel: +49 (0) 83 33 - 302-0 E-Mail: [email protected]

    Get Price
  • dilo vacuum Manufacturers

    DILO Products - Aspectus Engineering Services Pte Ltd. SF 6-gas recovery down to < 1 mbar; TM 5.0 B Oil-free Compressor; delivery rate: 6.5 m³/h at medium suction pressure with SF 6; Oil-free suction pump for recovery of SF 6 (15 m³/h, final vacuum < 1 mbar); Vacuum pump for evacuation of air (40 m 3 /h, final vacuum < 1 mbar); Operating and indication of the most important process

    Get Price
  • dilo vacuum retail

    Dilo B0464R13 Mobile Vacuum Pump Unit with Solenoid Valves. The mobile vacuum pump unit is convincing by its easy handling. The unit serves for evacuation of air or nitrogen from switchgear. The 40 m³/h vacuum pump enables a final vacuum of < 1 mbar. Thus it is guaranteed that no air / gas mixture is generated and the good. Get Price

edge-iconRelated News
toTop
Click avatar to contact us
Chat Online