DILO's path in sf6 gas handling started in 1967, when we supplied a complete piping system for installation of the first sf6-gas gas insulated switchgear. Since then, our product portfolio has successively been developed to the widest product range of emission-free gas handling equipment worldwide.

[email protected]

News Detail

  • SF6 Gas handling | Zero emissions and maximum gas re-use

    DILO's path in SF 6 gas handling started in 1967, when we supplied a complete piping system for installation of the first SF 6 gas insulated switchgear. Since then, our product portfolio has successively been developed to the widest product range of emission-free gas handling equipment worldwide.

    Get Price
  • PDF SF Gas Handling 6 - DILO

    gas handling. The path for the DILO brand in SF 6 gas handling was laid out in 1967 when the complete piping system for installation of the first SF 6 gas insulated switchgear was supplied by DILO. A good feel for the enormous market potential made DILO invest in SF 6 gas technology, launching the world's first SF 6 service cart only a few

    Get Price
  • DILO L400 SF6 service cart: emission free maintenance of

    When used with gastight DILO couplings and hoses, SF 6 emissions will have no chance! Short gas recovery and evacuating times are obtained by using a DN40 coupling. All L-Series SF 6 service carts are available with additional connecting DN20 and DN40 couplings (as an option) for simultaneous operation.

    Get Price
  • DILO Piccolo Series | SF6 gas reclaimer

    Piccolo Series SF 6 gas reclaimer for switchgear with reduced filling quantities. L030R02. The L030R02 model of the Piccolo series has been specially designed for modern switchgear with small gas compartments. Due to its compact construction this device fits conveniently onto a euro pallet for transport and is easily manoeuvrable even in the very narrow passage ways of gas insulated switchgear.

    Get Price
  • DILO SF6 valves and couplings for gas-insulated switchgear

    Whether for medium voltage switchgear, high voltage switchgear or gas-insulated lines (GIL) our products always meet your requirements. The DILO seal principle prevents the loss of SF 6 gas and moisture from penetrating the SF 6 gas system. DILO couplings eliminate the loss of SF 6 gas by incorrect gas handling.

    Get Price
  • SF6-alternative gases INSULATED SWITCHGEAR value

    SF6-alternative gases INSULATED SWITCHGEAR value. The SF6 Gas Insulated Switchgear Market report provides a detailed analysis of the dynamic of the market with extensive focus on secondary research. The report sheds light on the current situation of the market size, share, demand, development patterns, and forecast in the coming years.

    Get Price
  • DN20 Quick Disconnect Coupling- for easy - us.dilo.com

    DN20 Quick Disconnect Coupling For easy coupling and uncoupling of hoses. 3-1121-R003 The quick disconnect coupling is very useful in all fields of application where hoses have to be frequently loosened and reconnected e. g. during final tests of completely mounted GIS fields.

    Get Price
  • Siemens Gas Insulated Switchgear

    Siemens Gas Insulated Switchgear. The switchgear is a new addition to the 8DA and 8DB product family and also works with the proven vacuum switching technology. A vacuum-interrupter unit handles switching and arc extinguishing, while the natural gas insulates the current-carrying conductors inside the housing of the metal-encapsulated gas

    Get Price
  • SF6-alternative gases maintenance kit

    SF6-alternative gases maintenance kit. Oil Gas Product Support How Job Site Solutions Fleet Management Works Fleet management works when we work with you to define your availability, productivity, cost and efficiency goals, develop a high-performance plan with you and your local Cat® dealer to achieve the targeted results, and much more.

    Get Price
  • Wika Gas Insulated Switchgear maintenance

    Wika Gas Insulated Switchgear maintenance. Gas-insulated padmounted switchgear is designed and tested in accordance to with ANSI standard C37.60 and C37.72. The IEEE C37.20.9 standard for gas-insulated switchgear was released in the summer of 2019, prior to this GIS switchgear is designed, manufactured, and tested to International

    Get Price
  • Gas Insullated Switchgear sf6-gas gas filling kit separating unit

    Gas Insullated Switchgear SF 6 gas filling kit separating unit. SF6 GAS | Dilo Company, Inc 6 is a non-toxic, inert insulating and quenching gas of high dielectric strength and thermal stability. Thus, it is used in enclosed medium and high voltage switchgear as an arc quenching and insulating gas due to its properties.

    Get Price
  • Professional SF6 gas handling equipment and services - DILO

    SF 6 is a non-toxic, inert insulating and quenching gas of high dielectric strength and thermal stability. Due to its first-class properties it is used in enclosed medium and high voltage switchgear as an arc quenching and insulating gas.

    Get Price
  • PDF SF6 Free HV GIS and Breakers - US EPA

    Purpose Share status on replacement of SF6 with environmentally friendly insulating gas for high voltage GIS and breakers. SDGE, SCE, SMUD, LADWP PGE EPRI ABB, GE, Hitachi Siemens 3M Discussion on the Eco Gas replacement for SF6 November 29, 30 2016 What we learned 2

    Get Price
  • DN20 Quick Disconnect Coupling- for easy coupling - DILO

    DN20 Quick Disconnect Coupling For easy coupling and uncoupling of hoses. 3-1121-R003 The quick disconnect coupling is very useful in all fields of application where hoses have to be frequently loosened and reconnected e. g. during final tests of completely mounted GIS fields.

    Get Price
  • SF6 gas handling - DILO

    What are the most important factors of quality criteria for SF 6 gas in gas insulated switchgear (GIS)?. The following is of great importance: gas density, moisture concentration, decomposition products, gas purity (air concentration) which are determined by means of special SF 6 measuring instruments as well as gas density controllers. DILO supplies the measuring devices required for the

    Get Price
  • An alternative to SF6 in electrical switchgear - EE Publishers

    Due to its excellent properties for electric insulation and arc interruption, SF 6 enables safe and reliable operations while making it possible to reduce the size of switchgear installations significantly. However, SF6 is a greenhouse gas and the life-cycle management costs incurred when handling SF6, particularly when the decommissioning of ageing substations is on the increase.

    Get Price
  • DILO L600 SF6 service cart: emission free maintenance of

    The L-Series SF 6 service cart is our most powerful device and guarantees quick maintenance of gas compartments. The L600 features an oil-less suction pump in addition to the standard equipment included on the L400. Thanks to the state-of-the art control panel, all functions run automatically and are displayed on a 10 multi-touch screen.

    Get Price
  • Measuring device for<bRdecomposition products | DILO GmbH

    Measuring device for different decomposition products and gas residues For precise measurement. 3-032-R003 During the operation of gas insulated switchgear decomposition products might occur after a breakdown which has a negative impact on the gas quality in the circuit breaker as well as on the insulation properties.

    Get Price
  • ALTERNATIVE GASES | DILO GmbH

    Alternative gases as SF 6 substitute Focus on the environment. SF 6 is an excellent quenching and insulating gas which has been used in the energy sector worldwide for more than 50 years. The energy related development in the high and extra high voltage range would have been impossible without the use of SF 6 with its excellent dielectric stability and good electric arc quenching properties.

    Get Price
  • SF6 Gas Insulated Switchgear(GIS) Manufacturers and

    SF6 Gas Insulated Switchgear. As one of the leading manufacturers of medium voltage SF6 gas-insulated switchgear(GIS) in China, Orecco designed the gas-insulated switchgear for the secondary voltage distribution network in 6 different configurations. s is suitable for most switching applications in 11KV/33KV secondary distribution networks.

    Get Price
  • Two SF6 alternative gases in future - Switchgear Content

    Global warming will be a major issue in the future then using SF6 for switching equipment and high consumption of SF6 gas will decrease in the future Fig show fluoroketone (left) and fluoronitrile (right) molecular structures. They both have a carbon backbone, with 5 and 4 atoms, respectively. Both the fluoroketone and fluoronitrile have a

    Get Price
  • SF6 gas in medium-voltage switchgear | TD Guardian

    It is also used in gas-insulated substations (GIS) and gas-insulated lines (GIL), highly suited to urban power transmission applications. In the medium-voltage realm (up to 38kV), SF6 has been used outside the United States for circuit breakers having relatively low interrupting ratings.

    Get Price
  • Siemens develops SF6-free gas-insulated medium-voltage

    The switchgear is a new addition to the 8DA and 8DB product family and also works with the proven vacuum switching technology. A vacuum-interrupter unit handles switching and arc extinguishing, while the natural gas insulates the current-carrying conductors inside the housing of the metal-encapsulated gas-insulated switchgear (GIS).

    Get Price
  • Compact Series | DILO GmbH

    Compact Series For easy SF6 recovery and maintenance on high voltage switchgear. B057R.. This robust series comprises several versions allowing gaseous and liquid SF 6 storage. SF 6 gas can be recovered to a final vacuum of < 5 mbar or 1 mbar and exceeds IEC 62271-4 regulations by far.. All devices of this type series are equipped with a semi-automatic control and are easy to operate: The

    Get Price
  • SF6-alternative gases for application in gas-insulated

    6), which is the preferred gas for use in gas-insulated switchgear (circuit breakers, disconnect switches, etc. for high-voltage electrical circuits), has a very high global warming potential, and there is a large international effort to find alternative gases.

    Get Price
  • sf 6 gas recharge kit dilo - rvcarcare.nl

    SF6 GAS | Dilo Company, Inc. DILO's path in SF 6 gas handling started in 1967, when we supplied a complete piping system for installation of the first SF 6 gas insulated switchgear. Since then, our product portfolio has successively been developed to the widest product range of emission-free gas handling equipment worldwide. Get Price

    Get Price
  • International | DILO GmbH

    International regulations and guidelines SF 6 gas. Kyoto Protocol / Paris Agreement SF 6 gas is listed in the Kyoto protocol [external] as one of the six greenhouse gases subject to monitoring. SF 6 has to be used in closed systems in order to avoid emissions. 191 member states agreed to extend the Kyoto protocol until 2020 with the aim of reducing the emission of greenhouse gases.

edge-iconRelated News
toTop
Click avatar to contact us
Chat Online