Solvay fulfills even a higher specification than that required by IEC 60376, as illustrated in Table 1. In order to be able to transform the used SF. 6 . gas back into new virgin SF. 6 . the used gas must fulfill the so-called SF. 6 - ReUse - Specification in Table 2. In addition the material must be of one sort only and shall not be ...

[email protected]

News Detail

  • CEU SF6 Safety and Handling Trainings and Annual - DILO

    Trainings and Seminars Preventing SF 6 Emissions Through Awareness. DILO Company, Inc. and DILO Direct are committed to zero emissions of SF 6, which is why we place great value on SF 6 Safety and Handling Trainings. About 80% of manufactured SF 6 is used in high voltage equipment like switchgears and circuit breakers. We understand the importance of responsibly utilizing SF 6 in electrical

    Get Price
  • IEC specifications for SF6 gas - DILO

    Relevant IEC specifications/norms for SF6 gas are: IEC 60376 for new gas, IEC 60480 for used SF6 gas and IEC 62271-4 as SF6 reuse specification.

    Get Price
  • SF6 Refresher Training | DILO GmbH

    SF6 Refresher Courses based on EC Directive 517/2014 Practical experience for experts. Our new SF 6 Refresher Courses offer you the possibility to always stay up-to-date!. You can choose between a one-day and a two-day refresher course in order to be well prepared for facing the steadily growing challenges of the future.. In order to make the seminar efficient, the number of participants is

    Get Price
  • SF6 Safety and Handling Training | Training by DILO

    In-Person SF 6 Safety and Handling Training . Well-trained personnel are essential for safe, efficient and emission-free SF 6 gas handling. We used our 50 years of gas handling experience to develop a comprehensive SF 6 Safety and Handling Training Course. Your team will leave the course with the theoretical and practical knowledge they need to handle SF 6 gas.

    Get Price
  • Zero emissions and maximum gas re-use - DILO

    DILO SF 6 Gas Handling Zero emissions and maximum gas re-use. DILO's path in SF 6 gas handling started in 1967, when we supplied a complete piping system for installation of the first SF 6 gas insulated switchgear. Since then, our product portfolio has successively been developed to the widest product range of emission-free gas handling equipment worldwide.

    Get Price
  • PDF Environment ranks first - DILO

    as well as specifications for SF 6 re-use in switch-gear. For operation and SF 6 gas handling on site, the major parameter is gas purity stipulated by this standard. IEC 62271-4, Chart 6, No. 4 Further to procedures for safe and environmen-tally friendly handling of SF 6 during installation, commissioning, operation and end-of-life dispo-

    Get Price
  • SF6 gas handling - DILO

    After the separating process the gas complies with the quality criteria for reuse stipulated in the IEC 60480 directive. However, DILO separating units allow the SF 6 gas mixture to be purified to the extent that it even meets the standards of IEC 60376 (directive for new SF 6 gas technical quality) with regard to moisture, SF 6 percentage and

    Get Price
  • Professional SF6 gas handling equipment and services - DILO

    DILO SF 6 gas handling Zero emissions and maximum gas re-use. SF 6 is a non-toxic, inert insulating and quenching gas of high dielectric strength and thermal stability. Due to its first-class properties it is used in enclosed medium and high voltage switchgear as an arc quenching and insulating gas.

    Get Price
  • DILO Company, Inc. | World Leader in SF6 Maintenance Equipment

    If you're looking for a SF6 gas handling specialist that combines quality, innovation, and sustainability with excellent customer service, then DILO is for you. For over 50 years, customers around the world have valued DILO as an important partner for professional and emission-free SF6 gas handling.

    Get Price
  • PDF The SF6-ReUse-Process A contribution on the sustainability

    Solvay fulfills even a higher specification than that required by IEC 60376, as illustrated in Table 1. In order to be able to transform the used SF. 6 . gas back into new virgin SF. 6 . the used gas must fulfill the so-called SF. 6 - ReUse - Specification in Table 2. In addition the material must be of one sort only and shall not be

    Get Price
  • FAQ | DILO GmbH

    Why should I participate in the SF 6 certification training?. In accordance with the EU 517/2014 directive on fluor gas and the implementing EU 2015/2066 regulation only certified personnel is allowed to carry out the SF 6 gas handling (filling, measurement and reclaiming) in all EU member states.

    Get Price
  • Home - IEC Training

    Click on the Guest Link below to learn more about expert National Electrical Code Textbooks and Learning Resources, including A Complete Guide to the 2020 NEC Changes and A Comprehensive Guide to the 2017 NEC.

    Get Price
  • SF6 recovery - DILO

    SF 6 gas SF 6 gas recovery and re-use. Although SF 6 is an excellent insulating and quenching medium it is very important to know that. SF 6 is a fluorinated gas (F gas) with the highest global warming potential.; It is one of the six gases subject to monitoring under the Kyoto protocol. Relating to the greenhouse effect, 1 kg of SF 6 corresponds to a GWP value of more than 22,800 times higher

    Get Price
  • Hotel accommodation | DILO GmbH

    DILO Armaturen und Anlagen GmbH Frundsbergstrasse 36 D-87727 Babenhausen/Schwaben Tel: +49 (0) 83 33 - 302-0 E-Mail: [email protected]

    Get Price
  • FAQ | DILO GmbH

    Cancellations up to 14 days prior to the training are free of charge. For cancellations up to 7 days prior to the training we will invoice 50 %, and if cancellation is made on the day of training 100 % of the training costs are to be paid.

    Get Price
  • SF6 Certificate of Competence | DILO GmbH

    In the afternoon, you learn the practical skills and acquire knowledge on the DILO SF 6 service and measuring devices. On the second day the practical training, the theoretical and practical exam are held. In order to make the seminar efficient, the number of participants is limited to a maximum of 15. The minimum number of participants is six.

    Get Price
  • International | DILO GmbH

    IEC 62271-4 directive This directive stipulates SF 6 gas recovery down to a final vacuum of < 20 mbar. The IEC requirements are exceeded by far when using DILO devices as DILO service carts enable a final vacuum of < 1 mbar depending on the type of device. IEC 60480:2019 guideline

    Get Price
  • Sitemap - DILO

    DILO is a manufacturer of system solutions for the professional and emission-free management and handling of gases. Our portfolio is divided at the product level into SF6 Gas, Alternative Gases, Industrial Gas Equipment and High Pressure Products.

    Get Price
  • Reconditioned SF6 Gas - DILO

    Reconditioned SF 6 Gas Turn contaminated gas into a usable product. Over time, SF 6 gas used in GIE is often contaminated with air, nitrogen and/or tetrafluoromethane (CF4) due to leaks, inadequate evacuation, or incorrect gas handling. DILO Direct can recondition your contaminated SF 6 gas to exceed IEEE and IEC standards. With one call, DILO Direct will make all necessary arrangements to

    Get Price
  • PDF SF Gas Handling 6 - eknis.net

    The IEC 60480 directive also stipulates the limit values for the re-use of SF 6 gas. It is absolutely necessary to know the gas quality before carrying out maintenance works on a circuit breaker in order to be able to decide on preparation, re-use or disposal of the SF 6 gas. The essential quality criteria for SF 6 gas in circuit breakers are

    Get Price
  • Compact Series | DILO GmbH

    Compact Series For easy SF6 recovery and maintenance on high voltage switchgear. B057R.. This robust series comprises several versions allowing gaseous and liquid SF 6 storage. SF 6 gas can be recovered to a final vacuum of < 5 mbar or 1 mbar and exceeds IEC 62271-4 regulations by far.. All devices of this type series are equipped with a semi-automatic control and are easy to operate: The

    Get Price
  • White Paper - dilo.eu

    DILO Armaturen und Anlagen GmbH Frundsbergstrasse 36 D-87727 Babenhausen/Schwaben Tel: +49 (0) 83 33 - 302-0 E-Mail: [email protected]

    Get Price
  • Rules - us.dilo.com

    DILO service carts enable a final vacuum of < 1 mbar depending on the type of device. IEC 60480:2019 guideline This guideline stipulates the limit values for the re-use of SF 6 gas in medium and high voltage switchgear.

    Get Price
  • IEC Training

    The Industrial Emergency Council is the number one choice for fire department training. Whether you are looking for courses for Fire Command, Fire Instructor, Fire Management or anything in between, IEC has you covered.

    Get Price
  • SF6 Reconditioning - us.dilo.com

    DILO Direct can recondition your contaminated SF 6 gas to exceed IEEE and IEC standards. With one call, DILO Direct will make all necessary arrangements to have the gas picked up, reconditioned, and returned to you site in a like-new condition. We inspect every cylinder and guarantee our reconditioned gas to be: 99% SF 6 purity <40 ppm moisture

    Get Price
  • PDF Guidelines - Sulphur Hexafluoride Management

    IEC 60480:2004 Guidelines for the checking and treatment of sulfur hexafluoride (SF 6 ) taken from electrical equipment and specification for its re-use , International Electrotechnical Commission, available from SAI

    Get Price
  • Swedish Institute for Standards, SIS

    Guidelines for the checking and treatment of sulfur hexafluoride (SF6) taken from electrical equipment and specification for its re-use - IEC 60480:2004Concerns the re-use of sulfur hexafluoride (SF6) after removal from electrical equipment (for maintenance, or at the end of life)

    Get Price
  • DILO Armaturen und Anlagen GmbH | LinkedIn

    DILO has been a specialist in SF6 gas handling for about 50 years. With approx. 300 employees and more than 60 representatives worldwide, DILO is a key technology partner for switchgear

    Get Price
  • PDF Questions Misconceptions about GIS SF6 Gas Systems

    Other common reference standards: 14 1/18/2012 IEC 60480: Guidelines for the Checking and Treatment of Sulfur Hexafluoride (SF6) taken from Electrical Equipment and Specification for its Re-use IEC 62271-1: High-voltage switchgear and control gear -Part 1 -Common specifications. ASTM D2472: Standard Specification for Sulfur Hexafluoride

    Get Price
  • IEC specifications re-use

    IEC specifications re-use. This document describes the REFURBISHMENT PROCESS following risk management concepts for the REFURBISHMENT of MEDICAL ELECTRICAL EQUIPMENT (MEE), MEDICAL ELECTRICAL SYSTEMS (MES) - which are covered by the IEC 60601 series of standards - or SUB-ASSEMBLIES and the RE-USE of COMPONENTS as a possibility for an extended life cycle for MEE/MES.