News Center
dilo Load break switch abb system

dilo Load break switch abb system

Break new ground. A cutting-edge molded case circuit-breaker range delivering a brand new product experience, with extreme performance and protection features up to 1200A, maximizing ease of use, integration and connectivity.

[email protected]

News Detail

  • MV indoor disconnectors, load break switches - ABB

    The current transformers of the combined version form the mounting base for the earthing switch contacts thus reducing the space required in the cubicle. Product scope . IEC/ANSI indoor switches, switch-fuse combinations, disconnectors and load break switches up to 38.5 kV; Key features . Wide operating temperatures range

    Get Price
  • ANSI indoor air-insulated load break switch VersaRupter - ABB

    ANSI indoor air-insulated load break switch VersaRupter The VersaRupter uses a puffer and nozzle system to quickly and efficiently extinguish the arc of full-load interruptions. The rated voltage - 4.76-38 kV, normal rated current: 200-1200 A.

    Get Price
  • IEC indoor air-insulated load break switch NALFWind - ABB

    IEC indoor air-insulated load break switch NALFWind New powerful switch-fuse combination developed specifically for the wind power industry The NALFWind is adapted to 36 kV - the voltage level which is now standard for both wind turbines and peripherals.

    Get Price
  • PDF Load Break Switch Type LBOR-II, Oil Immersed - ABB

    2 ABB General Description The ABB Type LBOR-II switch is a manually operated, two position, load make or break, oil immersed rotary switch. The LBOR-II switch is designed for use with distribution transformers (pad mounted or submersible) and self contained distribution switchgear. The LBOR-II switch is designed to

    Get Price
  • ABB Library - All Categories

    ABB Library is a web tool for searching for documents related to ABB products and services. Category. All Categories. ABB Channel Partners. ABB Industries and utilities FSG II and GSL II Outdoor Vacuum Load Break Switch and Vacuum Circuit Breaker. ID: LO1100205-200V1E, REV:-English.

    Get Price
  • PDF LBOR-II Tehcnical Guide - ABB

    Oil immersed load break switch Technical Guide Introduction The ABB LBOR-II switch is a manually operated, two position, load make or break, oil immersed rotary switch. The LBOR-II switch is designed for use with distribution transformers (pad-mounted or submersible) and self contained distribution switchgear. Features Weld-in mounting system

    Get Price
  • Joslyn Hi-Voltage air break switches | ABB US

    Joslyn Hi-Voltage load air switches are a cost effective attachment to convert an isolating switch into a load interrupter switch. Depending upon system voltage, grounding considerations of the system and the load and load characteristics, the Joslyn Hi-Voltage load air switch enables the switch to be used for full load interruption or for the reduced recovery voltage application of loop

    Get Price
  • ABB Library - All Categories

    Break new ground. A cutting-edge molded case circuit-breaker range delivering a brand new product experience, with extreme performance and protection features up to 1200A, maximizing ease of use, integration and connectivity.

    Get Price
  • Switches | ABB

    The switch family consists of a complete range of switch-disconnectors, switch fuses, transfer switches, bypass switches and fuses. ABB's switches are designed for flexibility and reliable performance in a wide variety of applications: power distribution for residential and industrial buildings, HVAC, water pumping stations, data centers and

    Get Price
  • Load-break switch type LBOR - Hitachi ABB Power Grids

    Load-break switch type LBOR The LBOR-II™ switch is a manually operated, two position, load make or break, oil immersed rotary switch. The LBOR-II switch is designed for use with distribution transformers (pad mounted or submersible) and self-contained distribution switchgear.

    Get Price
  • What is a Load Break Switch (LBS) | TheElectricalGuy - YouTube

    In this video you'll be able to learn about load break switch, where it is used and how to turn it ON and OFF. You'll also understand the purpose and advanta...

    Get Price
  • Manual operated switch-disconnectors - Switches | ABB

    ABB switch-disconnectors are designed, built and tested for the best possible performance. They are designed to be virtually maintenance-free across their entire extended lifespan and offer reliable performance in any and all possible circumstances.

    Get Price
  • Medium Voltage Indoor Switches and Disconnectors | ABB US

    Air and gas insulated switches, disconnectors, isolators and earthing switches up to 38.5 kV for indoor operation in MV switchgear or compact substation. Air-insulated switch disconnectors are suitable for cable sectionalizer, transformer and motor circuit switching, in secondary distribution substations for supplying lines, transformers and ring networks, can be combined with

    Get Price
  • IEC indoor secondary gas switch-disconnector GSec - ABB

    Medium Voltage indoor gas insulated load break switch for secondary distribution up to 24 kV, 800 A, 25 kA . Key benefits. Capability for application with frequent switching requirements; Easy application in wide range of configurations; Smart grid and network automation ready; Sealed for life in accordance with standard IEC 62271-1

    Get Price
  • PDF PRODUCT AND APPLICATION PRESENTATION, 2017 Indoor Switches

    - Load break switches and switch-fuse combinations are commonly applicable as line and transformer switches as economic alternative to circuit breakers - Capable to interrupt full range overload and short circuits current due to high breaking performance of fuses and automatic fuse tripping system IEC 62271-105 - Significant reduction of prospective current value due to extremely fast operating time of current limiting fuses

    Get Price
  • Load-break switch type LBOR - Hitachi ABB Power Grids

    Load-break switch type LBOR The LBOR-II™ switch is a manually operated, two position, load make or break, oil immersed rotary switch. The LBOR-II switch is designed for use with distribution transformers (pad mounted or submersible) and self-contained distribution switchgear.

    Get Price
  • PDF SECTOS - pole mounted SF6 gas insulated load break switch

    6 leakage of each switch is less than 0.1% per year. The independent spring operating mechanism adopt ABB patent spiral spring, provides a guaranteed load break and fault making capability by ensuring the opening and closing speed of the switch. Key features of the product - fully enclosed switch - no external moving parts

    Get Price
  • Indoor switch, capacitor, capacitor bank - ABB

    DS1 is the first synchronous switch isolated in dry air specifically devised and designed for capacitor banks. The perfect combination, regulated by the electronic control unit, between the semiconductors and synchronism with the network allows to increase reliability and efficiency and prolongs the life of

    Get Price
  • PDF VersaRupter 5 - 38 kV Load Interrupter Switch - ABB

    The basic load break switch includes the steel chassis, molded insulators, current-carrying parts, arc blades and chambers, and a snap action or stored energy operating mechanism. A number of options are available, including a choice of snap action or stored energy operating mechanisms, handle systems, interlocks, fuse bases, and control features.

    Get Price
  • PDF 2017.12.20 Sectos pole mounted SF6 load break switch - ABB

    Two-position load break switch are available for all NXA_ and NXB_ types. All NXB_ types are also available with an integrated earthing switch for safe and reliable earthing of the downstream line. This version is called a 3-position switch to differentiate from the standard 2-position switch. 6 Sectos pole mounted SF6 load break switch 12 3 2

    Get Price
  • Breakmaster V Medium Voltage LIS | ABB US

    Current Load Interrupter Switches (LIS) may provide poor fault current interrupting times, resulting in high arc-flash incident energy. ABB's Breakmaster V solution provides reduced Arc Flash incident energy levels for customers on their existing MV equipment.

    Get Price
  • PDF PRODUCT CATALOGUE -insulated Ring Main Unit - ABB

    • Aux. switch for load break switch 2NO + 2NC • Aux. switch for earth switch 2NO + 2NC • Aux. switch for fuse blown 1NO • Aux. switch for vacuum circuit-breaker 2NO+2NC • Capacitive voltage indication • Short circuit indicator • Cable cover for parallel cables • Ronis key interlocking system • Current measuring

    Get Price
  • PDF switchgear Reliable, low maintenance and economical for

    ABB VersaRupter or NAL switches are offered. The ABB load break switch is compact, economical, flexible and easy to use. The load break switch utilizes ABB's unique arc puffer extinguishing design. − ABB load break switches are available with a choice of two standard mechanisms − Three-phase gang operated quick-make, quick-break with

    Get Price
  • ABB Library - Outdoor Overhead Switches and Disconnectors

    ABB Library is a web tool for searching for documents related to ABB products and services. brightness_1 Category. All Categories. ABB Products. Medium Voltage Products and Systems outdoor overhead SF6 gas insulated switch-disconnector / load break switch / sectionalizer. Brochure. Brochure. 2018-03-08. PDF. file_download. 0,36 MB. PUBLIC

    Get Price
  • Circuit Breakers | GE Industrial Breakers | ABB US

    GE Industrial's Circuit Breakers are now ABB's Circuit Breakers. Get all the power of ABB and GE Industrial offering including Molded Cases, Miniature, Supplementary Protectors, Enclosed, Insulated Cases, Low and Medium Voltage, Remote Racking Devices, DC High Speed and Residential circuit breakers.

    Get Price
  • Circuit Breakers | ABB GE Industrial

    GE Industrial's Circuit Breakers are now ABB's Circuit Breakers. Get all the power of ABB and GE Industrial offering including Molded Cases, Miniature, Supplementary Protectors, Enclosed, Insulated Cases, Low and Medium Voltage, Remote Racking Devices, DC High Speed and Residential circuit breakers.

    Get Price
  • TNI - Load Break Switching and Fault Interrupting both

    The switches are designed for use on 3-phase systems with voltages up to 38kV, 630A load break and continuous current, with 12.5kA, 20kA, and 25kA symmetrical fault interrupting ratings. The switches are designed to IEEE C37.72, C37.74, and C37.60 for load break and fault interrupting capability.

    Get Price
  • PDF Molded Case Circuit Breakers Section 6 - ABB

    —Molded Case Switches The product numbers as shown in the following pages include the complete breaker or switch. All devices listed come with Cu/Al line and load lugs. If line lugs are not required on a breaker, eliminate WL from product number; for molded case switches see page 6-3. Unless otherwise noted, all circuit breakers are UL

    Get Price
  • Vertical-break disconnectors up to 245 kV

    Self-aligning, double motion contact system for stability at higher short circuit levels; Jaw type contacts at the hinge and far end; Special reverse loop contact design for higher short circuit withstand capability; Contact opening of greater than 90 degrees; Tested and proven design for operation in seismic and icy conditions