News Center
dilo vacuum IEC specifications technical

dilo vacuum IEC specifications technical

After the separating process the gas complies with the quality criteria for reuse stipulated in the IEC 60480 directive. However, DILO separating units allow the sf6 gas gas mixture to be purified to the extent that it even meets the standards of IEC 60376 (directive for new sf6-gas gas technical quality) with regard to moisture, sf 6 percentage and ...

[email protected]

News Detail

  • AFTER SALES - DILO Company, Inc. | Dilo Company, Inc

    Please fill out our contact form or call our technical support specialists at 727-376-5593 for assistance. Please call DILO After-Hours Technical support at 727-373-8794 for emergency help with DILO equipment or SF 6 gas service needs which require immediate attention outside of our normal business hours (M-F, 7:30 a.m. to 4:30 p.m. EST).

    Get Price
  • Gas handling unit for industrial gases - us.dilo.com

    Technical data: Compressors: 2 x 90 m³/h; 300 m³ vacuum pump with 1,000 m³/h Roots Blower; 250 m³ screw pump; 30 l dry filter; Electro-pneumatically controlled DN100 valves

    Get Price
  • DILO Company, Inc. | World Leader in SF6 Maintenance Equipment

    If you're looking for a SF6 gas handling specialist that combines quality, innovation, and sustainability with excellent customer service, then DILO is for you. For over 50 years, customers around the world have valued DILO as an important partner for professional and emission-free SF6 gas handling.

    Get Price
  • International | DILO GmbH

    The IEC requirements are exceeded by far when using DILO devices as DILO service carts enable a final vacuum of < 1 mbar depending on the type of device. IEC 60480:2019 guideline This guideline stipulates the limit values for the re-use of SF 6 gas in medium and high voltage switchgear.

    Get Price
  • Vacuum test chambers | DILO GmbH

    SF6 leak testing units - from small to extra large Model range LeakScanner SV Vacuum testing of smaller components (without gas handling) This model range with a chamber volume of approx. 50 - 500 l is the ideal solution for testing smaller components where gas handling can take place outside the test chamber.

    Get Price
  • Gas handling unit - DILO

    Technical data: - Compressors: 2 x 90 m³/h - 300 m³ vacuum pump with 1,000 m³/h Roots Blower - 250 m³ screw pump - 30 l dry filter - Electropneumatically controlled DN100 valves - Internal DN100 VA piping - Remote control via 10 touch panel. Do you have any questions or a specific application? We are pleased to help you.

    Get Price
  • SF6 gas handling - DILO

    After the separating process the gas complies with the quality criteria for reuse stipulated in the IEC 60480 directive. However, DILO separating units allow the SF 6 gas mixture to be purified to the extent that it even meets the standards of IEC 60376 (directive for new SF 6 gas technical quality) with regard to moisture, SF 6 percentage and

    Get Price
  • Data privacy - DILO

    IEC specifications for SF6 gas. Professional SF6 gas handling or objections regarding data processing by email to our Data Protection Officer at [email protected] or to the contact details specified under Art. 1. 3. Data Security. We maintain current technical measures in order to ensure data security, in particular for the

    Get Price
  • SF6 Certificate of Competence | DILO GmbH

    Practical training | Certificate of competence 2-day seminar with exam and certificate. In the two-day training the participants acquire the minimum technical knowledge and skills as defined in Annex 1 of the EU Regulation 2015/2066.

    Get Price
  • Xenon recovery | DILO GmbH

    Reuse of the recovered gas if the gas quality complies with the customer's specification or automatic supply of new gas in case the measured gas quality no longer meets the required criteria. Technical data - Oilfree compressor: 3.2 m³/h, 50 bar - Oilfree suction pump (for gas): 15 m³/h, < 0.1 mbar - Oilfree vacuum pump (for air): 15 m³/h

    Get Price
  • Service Request online | DILO GmbH

    DILO Armaturen und Anlagen GmbH Frundsbergstrasse 36 D-87727 Babenhausen/Schwaben Tel: +49 (0) 83 33 - 302-0 E-Mail: [email protected]

    Get Price
  • DILO Asia-Pacific Pte. Ltd.

    DILO Asia Pacific Our service centre in close proximity to the customer. We want to be there where our customers are, closeness to customers ranks first at DILO. In 2013 our service center DILO Asia-Pacific Pte. Ltd. was founded with the target to further improve our global services, especially for our customers in the Asia-Pacific region.

    Get Price
  • PDF Norme Internationale

    5 Dry vacuum cleaning tests The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as IEC Publication(s) ). Their

    Get Price
  • PDF SF Gas Handling 6 - eknis.net

    DILO's high technical standard and individual solution Vacuum pump. 6 Perfectly suited for gas handling with small gas compartments and gas reclaiming to < 5 mbar. For protection of staff in accordance with IEC direc-tives regarding working on open gas compartments.

    Get Price
  • PDF Chapter - 1 Technical Specification Parameters

    TECHNICAL SPECIFICATION PARAMETERS INTRODUCTION: 1. Ratings, Voltage Ratio, Tapping range, Impedance and other technical parameters may be selected as per CBIP Publication No. 295, Manual on Transformers, 2012. 2. This Manual gives the recommended losses for the standardised ratings of power transformers (Annexure - 1.1).

    Get Price
  • White Papers - us.dilo.com

    DILO Company, Inc. 11642 Pyramid Drive Odessa, FL 33556 Phone: 727-376-5593 E-Mail: [email protected]

    Get Price
  • Helium Leak Testing Unit - us.dilo.com

    Technical data - Leak detection system: mass spectrometer - Smallest detectable leak rate of the leak measurement system: 1x10-11 mbar l/s - Chamber size: approx.: 1.3 m³ - Pumping performance: 500 m³/h with final vacuum 1x10-3 mbar

    Get Price
  • PDF International Standard Norme Internationale

    IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC/ASTM 62885-6 has been prepared by a Joint Working Group of subcommittee 59F: Surface cleaning appliances, of IEC technical committee 59: Performance of household and similar electrical appliances and ASTM Committee F11: Vacuum cleaners.

    Get Price
  • Welcome to the IEC Webstore

    The International Electrotechnical Commission is the international standards and conformity assessment body for all fields of electrotechnology. The IEC site includes information about electric, electronic and electrotechnical international standards, compliance and conformity assessment for electronics and electronic equipment, and international electrical standards information.

    Get Price
  • PDF Technical Specification

    Technical Specification LED luminaires - requirements 3 Foreword This Technical Specification presents the requirements for outdoor LED luminaires. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. In this Technical Specification, the following print types are used: - requirements: Arial type. - references

    Get Price
  • Insight into the technical aspects of vacuum cleaners - V

    The large European manufacturers of vacuum cleaners have worked out a standard describing how the various properties are to be defined and measured. IEC 312 / DS/EN 60312 Vacuum Cleaners for Use in the Household - Methods for Measuring the Utility Properties. If you want to compare various vacuu

    Get Price
  • DILO - B057R.. - Compact Series - DILO - SF6 Service Carts

    Technical data: Dimensions: L 1,850 mm, W 950 mm, H 1,220 mm; Weight: 580 kg; Standard equipment: TM 5.0 B oilfree DILO compressor; delivery rate: 6.5 m³/h at medium suction pressure with SF6; Vacuum compressor for recovery of SF6 (4.8 m3/h, final vacuum < 5 mbar) Vacuum pump for evacuation of air (40 m3/h, final vacuum < 1 mbar) Evaporator

    Get Price
  • PDF Medium Voltage technical guide - Electrical Engineering Portal

    For technical and economic reasons, the service voltage of medium voltage specifications incorporates a note in its scope: For the use of this standard, high voltage (see IEV 601- • IEC 60076-16 transformers for wind turbine applications. According to the application guide, IEC 60076-8, it is intended to provide information

    Get Price
  • Compact sf6 gas vacuum in CHILE - schallmarkus.de

    new sf6-gas vacuum and filling in NIGER. Portable SF6 gas refilling device | DILO GmbH 6 gas refilling device For reliable refilling of SF 6 gas by overpressure. 3-393-R001 SF 6 gas refilling device for high voltage Portable with rubber hose and couplings DN8 and DN20, Pressure range 0 up to 10 bar. 3-393-R002 SF 6 gas refilling device for high voltage Portable in a case with rubber hose and

    Get Price
  • Myth About SF6 Gas In Electrical Equipment

    Buildings containing SF6-filled indoor equipment should be provided with ventilation; natural ventilation would normally be adequate to prevent the accumulation of SF6 released due to leakage (see IEC 61634, sub-clause 3.4: Safety of personnel and IEC 61936-1). Type and extent of required measures depend upon location of the room, the

edge-iconRelated News
toTop
Click avatar to contact us